menu
A &
S Thai Works Co., Ltd.
98/7 Theparak Rd., Km.22
Bangsaothong, Samutprakarn
10540 Thailand
Ph: 66 2 313 1540
Fax: 66 2 313 1550
Email: astw@ksc.th.com |
|
|
|
| |
| |
| |
|
| |
Fishmeal plant LFP-C 24 |
|
|
| |
| |
|
| |
Fishmeal plant LFP-C 55  |
|
|
| |
Fish meal plants LFP-C 24 or LFP-C 55 for lean
fish, fish-waste and tuna-waste.
24 or 55 tons input per 24 hours = 1,000 or 2,300
kg/h. The plants are mounted on one or two 40
foot container
flat racks, it is complete with boiler and tanks,
by hook up electricity, fuel and water and just
start up.
ASTW has manufactured more than
160 plants in South East Asia, Pacific, Middle
East, Australia and New Zealand.
The plant is a heavy duty design manufactured
to the highest specification and with the highest
quality available.
Note: For trawler fish contaminated
with sand, stone and shell, a heavy-duty drier
with extra disc wear-protection
(U-caps) can be ordered as an option.
|
| |
| Technical
data: |
| Capacity
|
:
24 / 55 tons input/24 hrs. (Approx. 1,000
/ 2,300 kg/hr.)
expect some variation depending
on type of fish. |
| Raw material
|
:
Fresh and clean lean fish, fish-waste and
tuna-waste with maximum oil content
2.5-3.0 % which gives maximum
oil content in the fish meal 12-15%. |
| Process |
:
LFP = Lean Fish Processing, drying without
oil extraction, thereafter
cooling, (screening) grinding,
cooling again and bagging of the fish meal. |
| Components |
:
See enclosed technical description. |
Approbation
of
pressure vessel (drier) |
:
Certified to British Standard BS/PD 5500 cat.2
(2000) by Lloyds'
Registered Office, Bangkok |
|
| |
Technical
Specification:
Nominal capacity 24/55 tons/24 hrs. Based
on fresh, clean fish.
|
|
Plant
Size |
LFP
– C 24 |
LFP – C
55 |
|
Steam consumption
at 6 bar |
1.0 tons/h. |
2.3 tons/hr. |
|
Boiler size
(max. 10 bar) |
1.2 tons/h. |
3.0 tons/hr. |
|
Fuel consumption
- heavy oil (75 liters/ton
steam)
- diesel oil (80 liters/ton
steam)
|
60 liters/h. |
160 liters/hr. |
|
Electric
Load kW. (60%) |
32 kW. (44 HP) |
67 kW. (91 HP) |
|
Electric
installed kW.
Note : KVA = kW/power factor
for motor 0.8 (95/0.8 = 118
KVA)
|
45
kW. (62 HP) |
95 kW. (130 HP) |
Cooling seawater required
for scrubber (inlet temp. max.
30°C) |
45 m3/h. |
94
m3/hr. |
|
Weight of complete unit |
Approx.
22 tons |
Approx.