class="tblborder">
 |
 |
Fishmeal plant LFP-C 24 |
Fishmeal plant LFP-C 55 |
Containerized Fishmeal Plants LFP-C 24 or LFP-C 55 for lean
fish, fish-waste and tuna-waste. These plants can process 24 or 55
tons input per 24 hours (1,000 or 2,300 kg/h). The LFP-C 24 plant
is mounted on 2 x 20 foot container flat rack. The LFP-C 55 is
mounted on 4 x 20 foot container flat racks. They both come
complete with boiler and tanks. By hooking up to electricity, fuel
and water the plants are ready for start up.
These plants are heavy duty design and manufactured to the
highest specification, with the highest quality components
available.
Note: For trawler fish contaminated with
sand, stone and shell, a heavy-duty drier with extra disc
wear-protection (U-caps) can be ordered as an option.
TECHNICAL DATA
style="width: 100%;">
Raw material: |
Fresh and clean lean fish, fish-waste and tuna-waste with maximum oil content 2.5-3.0 % which gives maximum oil content in the fish meal 12-15%. |
Process: |
Lean Fish Processing (LFP) is drying without oil extraction, followed by cooling of the meal, (screening) grinding, cooling again and bagging of the fishmeal. |
Certification of pressure vessel (drier): |
Certified to British Standard BS/PD 5500 cat.2 (2000), European Standard PED and Australian Standard AS1210 by Lloyd's International (Thailand) Ltd. |
Warranty Rotary Disc Drier*: |
3 years from date of start up, includes drier body, gear, beatings and motor.
( *south East Asia only, otherwise 1 year warranty) |
After sales service: |
ASTW Service Technicians are available for advice in our Bangkok office. |
Spare Parts: |
Genuine spare parts are carried in stock for all ASTW manufactured equipment. Contact our Sales & Marketing team for assistance. |
TECHNICAL SPECIFICATION
Nominal capacity 24/55 tons/24 hrs. Based on fresh, clean
fish.
style="width: 584px;">
|
LFP - C 24 |
LFP - C 55 |
Steam consumption at 6 bar
|
1.0 tons/h.
|
2.3 tons/hr.
|
Boiler size (max. 10 bar)
|
1.2 tons/h.
|
3.0 tons/hr.
|
Fuel consumption
- heavy oil (65 liters/ton steam)
- diesel oil (60 liters/ton steam)
|
60 liters/h.
|
138 liters/hr.
|
Electric Load kW. (70%)
|
42 kW. (56 HP)
|
75 kW. (100 HP)
|
Electric installed kW.
Note : KVA = kW/power factor
for motor 0.8 (60/0.8 = 75 KVA)
|
60 kW. (80 HP)
|
107 kW. (143 HP)
|
Cooling seawater required for scrubber
(inlet temp. max. 30 °C)
|
45 m3/h.
|
94 m3/hr.
|
Weight of complete unit
|
Approx. 22 tons
|
Approx. 40 tons
|
style="width: 100%;">
 |
LFP-C 24 LFP-C 55 |